I am completing the FCOE lab on INE datacenter workbook.  I have configured the devices as per the workbook.

When i log into the EMulex server i see the PWWN as the target mapping but when i go to server manager i do not see the remote disk.'s   i have rebooted the box 

 

what do i need to to get this recoginsed in server manager storage section

 

NK1

vlan 10

  name native

vlan 1101

  fcoe vsan 101

port-channel load-balance ethernet source-dest-port

 

vsan database

  vsan 101

fcdomain fcid database

  vsan 101 wwn 10:00:00:00:c9:99:f3:79 fcid 0x980000 dynamic

interface vfc111

  bind interface Ethernet101/1/1

  switchport trunk allowed vsan 101

  no shutdown

vsan database

  vsan 101 interface vfc111

 

interface fc2/1

  switchport trunk allowed vsan 101

  no shutdown

 

interface fc2/2

  switchport trunk allowed vsan 101

  no shutdown

 

interface Ethernet101/1/1
  switchport mode trunk
  switchport trunk native vlan 10
  switchport trunk allowed vlan 10,1101
  spanning-tree port type edge trunk
interface fc2/1
  switchport speed 2000
interface fc2/2
  switchport speed 2000
interface fc2/1
  switchport mode E
interface fc2/2
  switchport mode E
zone default-zone permit vsan 101
VSAN 101:
--------------------------------------------------------------------------
FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x630000    N     21:02:00:1b:32:44:5e:dc (Qlogic)        scsi-fcp:target
0x980000    N     10:00:00:00:c9:99:f3:79 (Emulex)        ipfc scsi-fcp:init
fc2/1 is trunking
    Vsan 101 is up (None)
fc2/2 is trunking
    Vsan 101 is up (None)
MDS 3
vsan database
  vsan 101
fcdomain fcid da
interface fc1/1
  switchport speed 2000
interface fc1/2
  switchport speed 2000
interface fc1/9
  switchport speed 2000
interface fc1/1
  switchport mode E
interface fc1/2
  switchport mode E
interface fc1/9
  switchport mode F
vsan database
  vsan 101 interface fc1/9
zone default-zone permit vsan 101
interface fc1/1
  switchport trunk allowed vsan 101
  no shutdown
interface fc1/2
  switchport trunk allowed vsan 101
  no shutdown
fc1/1 is trunking
    Vsan 101 is up (None)
fc1/2 is trunking
    Vsan 101 is up (None)
MDS3(config)# show fcns database
VSAN 101:
--------------------------------------------------------------------------
FCID        TYPE  PWWN                    (VENDOR)        FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x630000    N     21:02:00:1b:32:44:5e:dc (Qlogic)        scsi-fcp:target
0x980000    N     10:00:00:00:c9:99:f3:79 (Emulex)        ipfc scsi-fcp:init
AS you can  see the  pwwn are being registered the zone vsan 101 is permit 
I even see the target on the server 
but i can see the disk in server manager please help i am newish to storage 