I am completing the FCOE lab on INE datacenter workbook. I have configured the devices as per the workbook.
When i log into the EMulex server i see the PWWN as the target mapping but when i go to server manager i do not see the remote disk.'s i have rebooted the box
what do i need to to get this recoginsed in server manager storage section
NK1
vlan 10
name native
vlan 1101
fcoe vsan 101
port-channel load-balance ethernet source-dest-port
vsan database
vsan 101
fcdomain fcid database
vsan 101 wwn 10:00:00:00:c9:99:f3:79 fcid 0x980000 dynamic
interface vfc111
bind interface Ethernet101/1/1
switchport trunk allowed vsan 101
no shutdown
vsan database
vsan 101 interface vfc111
interface fc2/1
switchport trunk allowed vsan 101
no shutdown
interface fc2/2
switchport trunk allowed vsan 101
no shutdown
interface Ethernet101/1/1
switchport mode trunk
switchport trunk native vlan 10
switchport trunk allowed vlan 10,1101
spanning-tree port type edge trunk
interface fc2/1
switchport speed 2000
interface fc2/2
switchport speed 2000
interface fc2/1
switchport mode E
interface fc2/2
switchport mode E
zone default-zone permit vsan 101
VSAN 101:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x630000 N 21:02:00:1b:32:44:5e:dc (Qlogic) scsi-fcp:target
0x980000 N 10:00:00:00:c9:99:f3:79 (Emulex) ipfc scsi-fcp:init
fc2/1 is trunking
Vsan 101 is up (None)
fc2/2 is trunking
Vsan 101 is up (None)
MDS 3
vsan database
vsan 101
fcdomain fcid da
interface fc1/1
switchport speed 2000
interface fc1/2
switchport speed 2000
interface fc1/9
switchport speed 2000
interface fc1/1
switchport mode E
interface fc1/2
switchport mode E
interface fc1/9
switchport mode F
vsan database
vsan 101 interface fc1/9
zone default-zone permit vsan 101
interface fc1/1
switchport trunk allowed vsan 101
no shutdown
interface fc1/2
switchport trunk allowed vsan 101
no shutdown
fc1/1 is trunking
Vsan 101 is up (None)
fc1/2 is trunking
Vsan 101 is up (None)
MDS3(config)# show fcns database
VSAN 101:
--------------------------------------------------------------------------
FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE
--------------------------------------------------------------------------
0x630000 N 21:02:00:1b:32:44:5e:dc (Qlogic) scsi-fcp:target
0x980000 N 10:00:00:00:c9:99:f3:79 (Emulex) ipfc scsi-fcp:init
AS you can see the pwwn are being registered the zone vsan 101 is permit
I even see the target on the server
but i can see the disk in server manager please help i am newish to storage