Hello all,

 

I was wondering while forming a port-channel between FI and a MDS switch, is it nencassary to apply the command"switchport rate-mode dedicated" as given in the workbook. As far as I know this command is applied when the port type is "e". But when the port is of type f (or the MDS have a feature npiv) then there is no need to use this command. I use the following configuration if I have to form a port channel from MDS to FI and allow vsan10

 

feature npiv

feature fport-channel-trunk

interface fc1/7-8

channel-group 2 force

interface port-channel 2

channel mode active

sw mode f

sw trunk allowed vsan 10

no shut

 

vsan database

vsan 10

vsan 10 interface po2

 

 