Hi Guys,
I had some problem today during my lab on dcrack5 (UCS).
I got the service-profile ESXi1 to boot, but got an PSOD after a while (still during boot), i have an screenshot of the PSOD if anyione wants it.
The second service-profile ESXi2, i can't boot at all, i have tried everything.
- i followed the labguide to use lun 2 for ESXi2 service-profile
- i have also tried lun 0 for booting the ESXi2 service-profile
- i can see both the server and disk-array logged in to the mds, ie sh flogi database
- i can see both the server and disk-array in the zoning as allowed, sh zone active vsan 101|102
here are the output from some of my commands:
MDS1# sh flogi database
--------------------------------------------------------------------------------
INTERFACE VSAN FCID PORT NAME NODE NAME
--------------------------------------------------------------------------------
fc2/3 101 0x910100 21:00:00:1b:32:04:5e:dc 20:00:00:1b:32:04:5e:dc
[SAN_ARRAY1_Faba]
port-channel 2 101 0x910002 24:64:00:2a:6a:c0:22:00 20:65:00:2a:6a:c0:22:01
port-channel 2 101 0x910004 20:aa:00:25:b5:c1:00:02 20:ff:00:25:b5:00:00:1f
[ESXi2-fc0]
Total number of flogi = 3.
MDS1# sh zone active vsan 101
zone name ESXi-12-boot-datastore vsan 101
pwwn 20:aa:00:25:b5:c1:00:01 [ESXi1-fc0]
* fcid 0x910004 [pwwn 20:aa:00:25:b5:c1:00:02] [ESXi2-fc0]
* fcid 0x910100 [pwwn 21:00:00:1b:32:04:5e:dc] [SAN_ARRAY1_Faba]