Hi,
today i was doing FCOE in INE rack but for some reason my VFC link towards Server is not coming up , i have did manytime in CISCO PEC lab link comes UP in a Sec but i don;t know why link is not coming UP here
below is Output i have taken...
please let me know if i am missing something here
N5K3# sh int vfc 1
vfc1 is trunking
Bound interface is Ethernet101/1/1
Hardware is Ethernet
Port WWN is 20:00:00:05:9b:1e:82:ff
Admin port mode is F, trunk mode is on
snmp link state traps are enabled
Port mode is TF
Port vsan is 101
Trunk vsans (admin allowed and active) (101)
Trunk vsans (up) ()
Trunk vsans (isolated) ()
Trunk vsans (initializing) (101)
N5K3# sh system internal dcbx info interface e101/1/1
Interface info for if_index: 0x1f640000(Eth101/1/1)
Interface info for if_index: 0x1f640000(Eth1/1)
tx_enabled: TRUE
rx_enabled: TRUE
dcbx_enabled: TRUE
DCX Protocol: CEE
DCX CEE NIV extension: disabled
N5K3# sh vsan membership
vsan 101 interfaces:
vfc1
N5K3# show vlan fcoe
Original VLAN ID Translated VSAN ID Association State
---------------- ------------------ -----------------
101 101 Operational
interface Ethernet101/1/1
switchport mode trunk
switchport trunk native vlan 10
switchport trunk allowed vlan 10,101
spanning-tree port type edge trunk
N5K3# sh queuing interface e101/1/1
Ethernet101/1/1 queuing information:
Input buffer allocation:
Qos-group: 1
frh: 3
drop-type: no-drop
cos: 3
xon xoff buffer-size
---------+---------+-----------
8960 14080 24320
Qos-group: 0
frh: 8
drop-type: drop
cos: 0 1 2 4 5 6
xon xoff buffer-size
---------+---------+-----------
0 117760 126720
Queueing:
queue qos-group cos priority bandwidth mtu
--------+------------+--------------+---------+---------+----
2 0 0 1 2 4 5 6 WRR 50 1600
3 1 3 WRR 50 2240
storage controller --CISCO VIC FCOE Storport Miniport